Pennant PT25-20, PT25-25L
MAINTENANCE: This product can be maintained inline without disturbing the piping connections. Ensure that the trap is isolated - upstream & downstream - before attempting to dismantle it. It is recommended that the trap be opened periodically and the internals inspected for wear, damage, and dirt. All worn or damaged parts should be replaced with new spares. A full new internal kit comprising of the valve pin, valve seat, bracket and lever, should be replaced as a set. The bucket vent hole should be cleaned. The strainer screen should be removed and cleaned regularly. Ensure that the trap is primed by opening the inlet valve only a crack at start-up, allowing water to fill the trap before the steam enters. The trap should be installed as close as possible to the equipment to be drained. For new pipelines, ensure that the lines are properly flushed, prior to fitting the trap IMPORTANT: The inlet valve should be opened fully only after the trap is filled with water. DESCRIPTION: FEATURES: Inverted bucket steam trap with integral strainer and all stainless steel internals. Best suited for equipment drains with medium to heavy condensate loads. Intermittent operation. The inverted bucket arrangement operates on the density difference between steam and water, giving a cyclic operation for discharge of the accumulated condensate. High condensate handling capacities even at low pressure, permit the use of small trap sizes to suit many applications. The valve and valve seat are hardened by a special induction hardening process to withstand continuous prolonged operation. Perfect shut-off, no steam loss. SIZES : ½", ¾", 1", 1½", 2" CONNECTIONS: Screwed (NPT) / Socket weld / Flanged (welded on) INSTALLATION: The trap should be fitted with the inlet and outlet connections horizontally in-line. Correct fitment with body vertical is essential for easymovement of the bucket. Care must be taken to ensure that the trap level is below the level of the equipment to be drained. The bypass arrangement should be above the level of the trap. Full port isolation valves should be fitted before and after the trap, to be used when the trap has to be opened for maintenance. LIMITINGCONDITIONS: Max. pressure rating 350 psig Max. temperature rating 800ºF (½" to 1" size) 650ºF (1½" & 2" size) Maximum operating back pressure at the outlet should not exceed 90% of the inlet pressure. Minimum diff. pressure for satisfactory operation 1.5 psi
Request a Quote
Availability:
In stock
SKU
PE01500W
MAINTENANCE: This product can be maintained inline without disturbing the piping connections. Ensure that the trap is isolated - upstream & downstream - before attempting to dismantle it. It is recommended that the trap be opened periodically and the internals inspected for wear, damage, and dirt. All worn or damaged parts should be replaced with new spares. A full new internal kit comprising of the valve pin, valve seat, bracket and lever, should be replaced as a set. The bucket vent hole should be cleaned. The strainer screen should be removed and cleaned regularly. Ensure that the trap is primed by opening the inlet valve only a crack at start-up, allowing water to fill the trap before the steam enters. The trap should be installed as close as possible to the equipment to be drained. For new pipelines, ensure that the lines are properly flushed, prior to fitting the trap IMPORTANT: The inlet valve should be opened fully only after the trap is filled with water. DESCRIPTION: FEATURES: Inverted bucket steam trap with integral strainer and all stainless steel internals. Best suited for equipment drains with medium to heavy condensate loads. Intermittent operation. The inverted bucket arrangement operates on the density difference between steam and water, giving a cyclic operation for discharge of the accumulated condensate. High condensate handling capacities even at low pressure, permit the use of small trap sizes to suit many applications. The valve and valve seat are hardened by a special induction hardening process to withstand continuous prolonged operation. Perfect shut-off, no steam loss. SIZES : ½", ¾", 1", 1½", 2" CONNECTIONS: Screwed (NPT) / Socket weld / Flanged (welded on) INSTALLATION: The trap should be fitted with the inlet and outlet connections horizontally in-line. Correct fitment with body vertical is essential for easymovement of the bucket. Care must be taken to ensure that the trap level is below the level of the equipment to be drained. The bypass arrangement should be above the level of the trap. Full port isolation valves should be fitted before and after the trap, to be used when the trap has to be opened for maintenance. LIMITINGCONDITIONS: Max. pressure rating 350 psig Max. temperature rating 800ºF (½" to 1" size) 650ºF (1½" & 2" size) Maximum operating back pressure at the outlet should not exceed 90% of the inlet pressure. Minimum diff. pressure for satisfactory operation 1.5 psi