DESCRIPTION:

FEATURES:

Inverted bucket steam trap with integral strainer and

all stainless steel internals. Best suited for

equipment drains with medium to heavy condensate

loads. Intermittent operation.

The inverted bucket arrangement operates on the

density difference between steam and water, giving

a cyclic operation for discharge of the accumulated

condensate.

High condensate handling capacities even at low

pressure, permit the use of small trap sizes to suit

many applications.

The valve and valve seat are hardened by a special

induction hardening process to withstand

continuous prolonged operation.

Perfect shut-off, no steam loss.

SIZES : ½", ¾", 1", 1½", 2"

CONNECTIONS: Screwed (NPT) / Socket weld /

Flanged (welded on)

INSTALLATION:

The trap should be fitted with the inlet and outlet

connections horizontally in-line. Correct fitment with body

vertical is essential for easymovement of the bucket. Care

must be taken to ensure that the trap level is below the

level of the equipment to be drained. The bypass

arrangement should be above the level of the trap.

Full port isolation valves should be fitted before and after

the trap, to be used when the trap has to be opened for

maintenance.

LIMITINGCONDITIONS:

Max. pressure rating 350 psig

Max. temperature rating 800ºF (½" to 1" size)

650ºF (1½" & 2" size)

Maximum operating back pressure at the outlet

should not exceed 90% of the inlet pressure.

Minimum diff. pressure for

satisfactory operation 1.5 psi

Request a Quote
Availability: In stock
SKU
PE01600W

DESCRIPTION:

FEATURES:

Inverted bucket steam trap with integral strainer and

all stainless steel internals. Best suited for

equipment drains with medium to heavy condensate

loads. Intermittent operation.

The inverted bucket arrangement operates on the

density difference between steam and water, giving

a cyclic operation for discharge of the accumulated

condensate.

High condensate handling capacities even at low

pressure, permit the use of small trap sizes to suit

many applications.

The valve and valve seat are hardened by a special

induction hardening process to withstand

continuous prolonged operation.

Perfect shut-off, no steam loss.

SIZES : ½", ¾", 1", 1½", 2"

CONNECTIONS: Screwed (NPT) / Socket weld /

Flanged (welded on)

INSTALLATION:

The trap should be fitted with the inlet and outlet

connections horizontally in-line. Correct fitment with body

vertical is essential for easymovement of the bucket. Care

must be taken to ensure that the trap level is below the

level of the equipment to be drained. The bypass

arrangement should be above the level of the trap.

Full port isolation valves should be fitted before and after

the trap, to be used when the trap has to be opened for

maintenance.

LIMITINGCONDITIONS:

Max. pressure rating 350 psig

Max. temperature rating 800ºF (½" to 1" size)

650ºF (1½" & 2" size)

Maximum operating back pressure at the outlet

should not exceed 90% of the inlet pressure.

Minimum diff. pressure for

satisfactory operation 1.5 psi