  1. Pennant PT25 Series Inverted Bucket Steam Traps
    The Model PT25 inverted bucket steam trap with integral strainer and all stainless steel internals is best suited for equipment drains with medium to heavy condensate loads. Intermittent operation. The inverted bucket arrangement operates on the density difference between steam and water, giving a cyclic operation for discharge of the accumulated condensate. High condensate handling capacities even at low pressure, permit the use of small trap sizes to suit many applications. The valve and valve seat are hardened by a special induction hardening process to withstand continuous prolonged operation. Learn More
    Request a Quote
    Buy Now
  2. Pennant PT25-25

    DESCRIPTION:

    FEATURES:

    Inverted bucket steam trap with integral strainer and

    all stainless steel internals. Best suited for

    equipment drains with medium to heavy condensate

    loads. Intermittent operation.

    The inverted bucket arrangement operates on the

    density difference between steam and water, giving

    a cyclic operation for discharge of the accumulated

    condensate.

    High condensate handling capacities even at low

    pressure, permit the use of small trap sizes to suit

    many applications.

    The valve and valve seat are hardened by a special

    induction hardening process to withstand

    continuous prolonged operation.

    Perfect shut-off, no steam loss.

    SIZES : ½", ¾", 1", 1½", 2"

    CONNECTIONS: Screwed (NPT) / Socket weld /

    Flanged (welded on)

    INSTALLATION:

    The trap should be fitted with the inlet and outlet

    connections horizontally in-line. Correct fitment with body

    vertical is essential for easymovement of the bucket. Care

    must be taken to ensure that the trap level is below the

    level of the equipment to be drained. The bypass

    arrangement should be above the level of the trap.

    Full port isolation valves should be fitted before and after

    the trap, to be used when the trap has to be opened for

    maintenance.

    LIMITINGCONDITIONS:

    Max. pressure rating 350 psig

    Max. temperature rating 800ºF (½" to 1" size)

    650ºF (1½" & 2" size)

    Maximum operating back pressure at the outlet

    should not exceed 90% of the inlet pressure.

    Minimum diff. pressure for

    satisfactory operation 1.5 psi

    Learn More
    Request a Quote
    Buy Now
  3. Pennant PT61 Float & Thermostatic Steam Traps
    The Model PT61 float and thermostatic (integral air vent) steam traps are designed for draining condensate from all types of low and medium pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers and jacketed vessels. Learn More
    Request a Quote
    Buy Now
  4. Pennant PT10 Thermodynamic Steam Trap
    The Model PT10 thermodynamic steam trap with inbuilt strainer in full stainless steel construction, is best suited for header and main line drains and drip legs. Complete stainless steel construction ensures better mechanical and corrosion resistance properties. Condensate entry below the disc, concentric to the disc / seat ensures a clean and parallel lift of the disc with reference to the seat, eliminating localized wear and tear. Learn More
    Request a Quote
    Buy Now
  5. Pennant PT21-40

    Inverted bucket steam trap with all stainless steel

    internals. Best suited for equipment drains with

    medium to heavy condensate loads. Intermittent

    operation.

    The inverted bucket arrangement operates on the

    density difference between steam and water, giving

    a cyclic operation for discharge of the accumulated

    condensate.

    High condensate handling capacities even at low

    pressures, permit the use of small trap sizes to suit

    many applications.

    The valve and valve seat are hardened by a special

    induction hardening process to withstand

    continuous, prolonged operation.

    Perfect shut-off, no steam loss.

     

    Sizes: ½", ¾", 1", 1½"

    Connections : Screwed (NPT)

     

    Max. pressure rating : 250 psig

    Max. temperature rating : 428 ºF

    Maximum operating back pressure at the outlet

    should not exceed 90% of the inlet pressure.

    Minimum diff. pressure for

    satisfactory operation : 1.5 psi

    DESCRIPTION:

    FEATURES:

    Learn More
    Request a Quote
    Buy Now
  6. Pennant PT62 Float & Thermostatic Steam Traps
    The Model PT62 float and thermostatic (internal air vent) steam traps are designed for draining condensate from all types of low and medium pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers and jacketed vessels. Learn More
    Request a Quote
    Buy Now
  7. Pennant PT31A Balanced Pressure Thermostatic Air Vent
    The PT31AV air vent is designed to remove air and non-condensible gases from steam systems. The removal of these gases is important for achieving better start-up efficiency and heat transfer in normal running. Learn More
    Request a Quote
    Buy Now
  8. Pennant PT21-20

    DESCRIPTION:

    FEATURES:

    Inverted bucket steam trap with all stainless steel

    internals. Best suited for equipment drains with

    medium to heavy condensate loads. Intermittent

    operation.

    The inverted bucket arrangement operates on the

    density difference between steam and water, giving

    a cyclic operation for discharge of the accumulated

    condensate.

    High condensate handling capacities even at low

    pressures, permit the use of small trap sizes to suit

    many applications.

    The valve and valve seat are hardened by a special

    induction hardening process to withstand

    continuous, prolonged operation.

    Perfect shut-off, no steam loss.

     

    SIZES:½", ¾", 1", 1½"

     

    CONNECTIONS: Screwed (NPT)

    LIMITING CONDITIONS:

    Max. pressure rating : 250 psig

    Max. temperature rating : 428 ºF

    Maximum operating back pressure at the outlet

    should not exceed 90% of the inlet pressure.

    Minimum diff. pressure for

    satisfactory operation : 1.5 psi

     

     

     

     

     

     

    Learn More
    Request a Quote
    Buy Now
  9. Pennant PT21-25

    DESCRIPTION:
    FEATURES:
    Inverted bucket steam trap with all stainless steel
    internals. Best suited for equipment drains with
    medium to heavy condensate loads. Intermittent
    operation.
    The inverted bucket arrangement operates on the
    density difference between steam and water, giving
    a cyclic operation for discharge of the accumulated
    condensate.
    High condensate handling capacities even at low
    pressures, permit the use of small trap sizes to suit
    many applications.
    The valve and valve seat are hardened by a special
    induction hardening process to withstand
    continuous, prolonged operation.
    Perfect shut-off, no steam loss.

    Sizes ½", ¾", 1", 1½"
    Connections Screwed (NPT)

    LIMITING CONDITIONS:
    Max. pressure rating : 250 psig
    Max. temperature rating : 428 ºF
    Maximum operating back pressure at the outlet
    should not exceed 90% of the inlet pressure.
    Minimum diff. pressure for
    satisfactory operation : 1.5 psi

    Learn More
    Request a Quote
    Buy Now
  10. Pennant PT23-20
    PE01200W Short Description Learn More